Applications
exceeding model specifications listed gladly quoted separately.
Here is what
we need to know;
·
Flow Rate
·
Inlet /
Outlet Size
·
ALL inlet and
outlet ports on separators are 180 degrees apart.
We
have the ability to move these port locations on the same axis if desired for
special needs.
If fuel pump flow rates are not available from the engine or
equipment manufacturer, you can estimate the Gallons Per Hour / GPH by
taking Engine Horsepower (maximum) multiplied by 0.18 or GPH = HP X 0.18
Model #
Dimensions
Maximum Flow
3 X 8
X 500
3" OD X 10” OA X 1/2 NPT Ports 240 GPH/ 907 LPH
5 x 12 x
1
5" OD X 14 OA X 1 NPT
Ports 720 GPH/ 2722 LPH
5 x 16 x
1 5" OD X 18 OA X 1 NPT
Ports 960 GPH/ 3629 LPH
8 x 20 x
2
8" OD X 22.5 OA X 2” NPT
Ports
2400 GPH / 9072 LPH
8 x 29 x
1 8" OD X 31 OA X 1 NPT
Ports
2400 GPH/ 9072 LPH
With platform base
8 x 47 x
2
8" OD X 47 OA X 2 NPT
Ports
2400 GPH/ 9072 LPH
With platform base

8" OD X 47 OA X 2 NPT
Ports

16 x 74 OA x 4”
NPT 12,000 GPH/ 44900 LPH
Email US
Telephone
877-823-7075 9:00 AM-4:00 PM PST
Dieselcraft is a trade mark of The
Magnum Group LLC
Suitable for a variety of fuels. Consult
Dieselcraft.
Suitable for all Cummins, Detroit Diesel, Caterpillar,
Volvo, Yanmar, Duramax, Power Stroke, Duetz, John Deere,
Perkins, Daewoo and
other diesel engines